SHANGHAI MCP CORP

Product Search
Product catalogue

POWER SUPPLY

TEST INSTRUMENTS

EDUCATION EQUIPMENT

METERS

MACHINE

ACCESSORIES

Product Detail

Osciloscope probe

 
Details



PTL-936 SERIES

PROBE

Feature
.Bandwidth up to 100MHz
.Meet IEC-1010, 600Vpp, CATIII




SpecificationsPTL-936-60PTL-936-100
AttenuatorX1/X10
System Rise-time(ns)
23.3/3.5
System Bandwidth (3dB)MHzX1: DC-6MHzX1: DC-6MHz
X10: DC-60MHzX10: DC-100MHz
Voltage Max.X1: 300V (DC + Peak AC)
X10: 600V (DC + Peak AC)
Compensation range(pf)15~4520~45
Input Res.(Mohm)1/10
Input Cap.(Pf)X1: 85pF~120pF
X10: 18.5pF~22.5pF
Cable length120cm120cm




PTL938 SERIES

PROBE

Feature
.Bandwidth up to 200MHz
.with color cable marker rings
.Meet IEC-1010, 600Vpp, CATIII

.Bandwidth up to 200MHz
.with color cable marker rings
.Meet IEC-1010, 600Vpp, CATIII




SpecificationsPTL-938-20PTL-938-40PTL-938-60PTL-938-100PTL-938-200
AttenuatorX1/X10
System Rise-time(ns)
≤17.5ns≤8.75ns≤5.8ns≤3.5ns≤1.75ns
System Bandwidth (3dB)MHzX1: DC-6MHzX1: DC-6MHzX1: DC-6MHzX1: DC-6MHzX1: DC-6MHz
X10: DC-20MHzX10: DC-40MHz

X10: DC-60
MHz

X10: DC-100MHz

X10: DC-200
MHz

Voltage Max.X1: 300V (DC + Peak AC)
X10: 600V (DC + Peak AC)
Compensation range(pf)15~45/10~35
Input Res.(Mohm)1/10
Input Cap.(Pf)X1: 85pF~120pF
X10: 18.5pF~22.5pF
Cable length120cm120cm




PTL-940SERIES

PROBE

Feature

.Max. Test voltage up to 2kV
.Bandwidth up to 100MHz
.Meet IEC-1010, 2000Vpp, CATI




SpecificationsPTL-940-100
AttenuatorX100
System Rise-time (ns)
≤3.5ns
System Bandwidth (3dB) MHz100MHz
Voltage Max.2000V (DC + Peak AC)
Compensation range (pf)10~35
Input Res.(Mohm)100
Input Cap.(Pf)5pF
Cable length120cm




PTL-970 SERIES
PROBE

Feature
.Max. Test voltage up to 5kV




SpecificationsPTL971-30PTL971-50PTL975-30PTL975-50
AttenuatorX10X10X100X100
System Rise-time(ns)
≤1.15ns≤0.7ns≤1.15ns≤0.7ns
System Bandwidth (3dB)MHz300MHz500MHz300MHz500MHz
Voltage Max.1kV
(DC + Peak AC)
1kV
(DC + Peak AC)
5kV
(DC + Peak AC)
5kV
(DC + Peak AC)
Input Res.(Mohm)1010100100
Input Cap.(Pf)16166.56.5
Cable length130cm



PTL-960 SERIES

PROBE

Feature

.Bandwidth up to 500MHz
.With a metal-box which has high frequency
compensation hole for HF adjust on any oscilloscope
.Meet IEC-1010, 600Vpp, CATIII



SpecificationsPTL-960-25PTL-960-30PTL-960-50
AttenuatorX10
System Rise-time(ns)
≤1.4ns≤1.15ns≤0.7ns
System Bandwidth (3dB)MHzX1: DC-6MHzX1: DC-6MHzX1: DC-6MHz
X10: DC-250MHzX10: DC-300MHzX10: DC-500MHz
Voltage Max.600V (DC + Peak AC)600V (DC + Peak AC)600V (DC + Peak AC)
Compensation range(pf)9~309~259~25
Input Res.(Mohm)101010
Input Cap.(Pf)12~1510~1310~13
Cable length120cm120cm120cm



PTL-955 SERIES

PROBE

Feature

.Max. Test voltage up to 40kV



SpecificationsPTL-955-IPTL-955-IIPTL-955-III
AttenuatorX1000
System Rise-time(ns)
≤17.5ns
System Bandwidth (3dB)MHz20MHz
Voltage Max.10kV (DC + Peak AC)20kV (DC + Peak AC)40kV (DC + Peak AC)
Compensation range(pf)9~309~259~25
Input Res.(Mohm)1000
Input Cap.(Pf)0.5~1.5
Cable length120cm120cm120cm