www.mcpsh.com ISO9001:2000
Fax Us:86-21-52699261





HOME
ABOUT US

CONTACT US
 


TEST INSTRUMENT CATEGORY
 
  ST50 & 60 Series

ELECTRICAL SAFETY TESTER

Feature
.AC/DC withstand voltage test & ground bond test .Insulation resistance test(ST60)
.Arc detection
.Zero crossing turn-on,turn-off operation switch
.Controllable ramp-up time
.Ture RMS cut-off current measurement
.Automatic fail indicator of alarm lamp and buzzer
.VFD display
.Standard PLC interface
.Option RS-232,RS-485

Specification
AC/DC Withstanding Voltage Test
.Test Time:0.1~999S
.Accuracy:±(2%+2digits)
Insulation Resistance Test(ST6050,ST6051,ST6052,ST6053)
.Resistance Range:1~1000MΩ
.Voltage Range:250V,500V,1000V
.Accuracy:±(5%+5digits)
Input Voltage:110~127VAC±10%,220~240VAC±10% Switchable



ST6050

 
Model Output Voltage Output Current Test Capacity Size(W×H×D) Weight(kg)
ST5050 0~5KVAC 0~100mAAC 500VA 320×150×280mm 11
ST5051 0~5KVAC/DC 0~100/20mAAC/DC 500VA 320×150×280mm 11
ST5052 0~5KVAC 0~20mAAC 100VA 320×150×320mm 11
ST5053 0~5KVAC/DC 0~20/10mAAC/DC 100VA 320×150×280mm 11
ST5101 0~10KVAC/DC 0~20/10mAAC/DC 200VA 320×150×400mm 11
ST6050 0~5KVAC 0~100mAAC 500VA 320×150×320mm 12.5
ST6051 0~5KVAC/DC 0~100/20mAAC/DC 500VA 320×150×320mm 12.5
ST6052 0~5KVAC 0~20mAAC 100VA 320×150×320mm 12.5
ST6053 0~5KVAC/DC 0~20/10mAAC/DC 100VA 320×150×400mm 12.5
ST99 Series

ELECTRICAL SAFETY TESTE

Feature
.AC/DC withstanding voltage test,insulation resistance test,ground resistance test & Leakage
.Programmable test
.Fast sampling rate,high efficiency
.Large 320×240 graphic LCD
.50 memory units with 8steps in each
.True RMS leakage current measurement
.Standard PLC interface
.Option RS-232,RS-485,USB,GPIB

Specification
Withstanding Voltage Test
.Voltage Range:0.050~5.000KVAC 0.050~6.000KVDC
.Accuracy:±(2%+5digits)
.Test current:0.001~40mAAC 0.001~20mADC
.Accuracy:±(2%+2digits)
.Test time:0~999.9S
.Test frequency:50/60Hz
.Arc detection:0~40mAAC 0~20mADC
Insulation Resistance Test(ST9930/ST9932)
.Resistance Range:1MΩ~9.999GΩ
.Test Voltage: 100~1000VC
.Accuracy:±(2%+5V)
.Test time:0~999.9S



ST9930
Leakage current & Ground resistance test
Model Leakage Current Ground resistance
Voltage Range Test Current Transformer Test Current Test Range Accuracy Test time
ST9930 30~300V 0~20mA 300VA 1 1 1 1
ST9931 30~300V 0~20mA 300VA 3~30A 0~510mΩ ±(2%+2mΩ) 0~999.9S
ST9932 1 1 1 3~30A 0~510mΩ ±(2%+2mΩ) 0~999.9S

Power source:110~127VAC±10%,220~240VAC±10%,50Hz±2Hz/60Hz±2Hz
Dimension(W×H×D):380×155×545mm
Weight:30kg

Copyright © Shanghai MCP Corp, 2012. All Rights Reserved
Add: Fl.3(East),Blk.4, Bai Da Industrial Park,No.1030 Tong Pu Rd., Shanghai, China
Tel: 86-21-52695961
Fax:86-21-52699261|Zip: 200333|E-mail: sales@mcpsh.com