DQ3000

HAND HOLD DIGITAL STORAGE OSCILLOSCOPE

Features
.Dual channel, bandwith 20-60MHz
.Sample Rate(Real-time)100MHz up to 250MHz
.Oscilloscope and multimeter, 2 in 1.
.3.8 inch colour LCD displayer with high resolution
.Compact design for easy carrying
.High performance li-ion battery for long time operate(6H)
.Hard package for repetitious using



DQ3022
Large view
 
1 DQ3022 DQ3062

Bandwidth

20MHz 60MHz
Real time
sample rate
100MS/s 250MS/s
Display 3.8 inch color display with TFT panel(320x240 pixels)
Acquisition mode Normal, Peak detect, Averaging
INPUT
Input coupling DC, AC
Input impedance 1M±2% in parallel with 20pF±3pF
Probe attenuation factors 1x, 10x, 100x, 1000x
Max. input voltage 400V(PK-PK) CATII

HORIZONTAL SYSTEM

Saming range
10S/s~100MS/s 10S/s~250MS/s
Recoord length
Max. 6K points
Time base range 5ns/div~50s/div(step as 1~2~5) 5ns/div~50s/div(step as 1~2.5~5)
Time base accuracy 100ppm 400V (DC + ACp-p)

VERTICAL SYSTEM

Resolution
8 bits
Sensitivity 5mV/div~5V/div (input to BNC)
Position range ±50V (500mV~5V) ±2V (5mV~200mV)
Single bandwidth Full bandwidth
LF Respong(AC, -3dB) ≥5Hz( to BNC)
Rising time(typical on BNC) ≤17.5 ns
DC gain accuracy ±5%

TRIGGER

Trigger Modes
AUTO, NORM, Single, Edge, Video
Trigger sensitivity DC coupling: CH1 and CH2: 1div(DC~25M)
AC coupling: CH1 and CH2: 1div(50Hz~full bandwidth)
Trigger level range ±6 divisions from center screen
Trigger level accuracy ±0.3 divisions
Trigger sensitivity(Video) 2 div(PK-PK)
Line/field frequency(Video) Support NTSC, PAL and SECAM
MEASUREMENT SYSTEM
Cursors measurement ΔV, ΔT
Automatic measurement PK-PK, Averaging, RMS, Frequency, Circle
Waveform math +, -, x, ÷
Waveform storage 4 waveforms, 4 settings
Lissajou's figure Available
PROBE
Bandwidth DC to 6MHz(1x) DC~full bandwidth(10x)
Attenuation rate 1:1 (1x) 10:1 (10x)
Compensate range 10pf~35pf 10pf~35pf
Input impedance 1M±2% 1M±2%
Input capacitance 85pf~115pf 14.5pf~17.5pf
Input voltage 150V DC 300V DC

X-Y OPERATION

Sensitivity

5mV~5V/div, ±4%

X-axis bandwidth DC ~500KHz
Phase Error ≤3°DC ~ 50KHz

ADPATER

Output current
8.5V DC 1500mA
Li-ion battery Power supply 7.4V, 3500mA
DIGITAL MULTIMETER CHARACTERISTS
Input impdeance 10M
Voltage VDC: 400mV, 4V, 400V:±(1%+1 digit)
Max. input: DC 400V
VAC: 4V, 40V, 400V: ±(1%+3 digits)
Fuequency: 40Hz~400Hz
Max.input: AC 400V(virtual value)
Current DCA: 40mA, 400mA: ±(1.5%+1 digit)
DAA: 40±(1.5%+3 digit) 400mA:±(2%+1 digit)
20A:±(3%+3 digits)
20A:±(5%+3 digits)
Impedance 400:±(1%+3 digits) 4K, 40K, 400K, 4M:±(1%+1 digit)
40M:±(1.5%+3 digits)
Capacitance 51.2nF~100uF:±(3%+3 digits)
Diode 0V~1.5V
On/off measurement <50(±30) beeping

ACCESSORIES

Two probes, two multimeter leads, current measurement extend module, probe adjust pen, small capacitance mesurement module, USB cable(RS232 optional), adapter
Copyright © Shanghai MCP Corp, 2008. All Rights Reserved