www.mcpsh.com ISO9001:2000
Fax Us:86-21-52699261





HOME
ABOUT US

CONTACT US
 


TEST INSTRUMENT CATEGORY
 

 

DQ2000 Series

DIGITAL STORAGE OSCILLOSCOPE

Features
. 250MSa/s~1GSa/s sampling rate
. 2 X 512K words per channel record length
. FFT function
. Auto-setting for quick setup and waveform acquisition
. 5.7-inch color/black-white LCD display, multicolor interface available
. Advanced cursor modes:manual, auto and track
. USB-HOST/DEVICE, RS232 interface (not for DQ2025BN)


DQ2102CN

 
TechnicalData DQ2025BN/2042BN(E)/2062BN(E)
DQ2102BN(E)/2152BN(E)/2202BN(E)
DQ2025CN/2042CN(E)/2062CN(E)
DQ2102CN(E)/2152CN(E)/2202CN(E)
Display
Type 5.7" rectangle mono LCD 5.7" rectangle color LCD
Backlight intensity 60cd/m2
Display resolution 320 horizontal×240 vertical pixels
Display contrast Adjustable
VERTICAL SYSTEM
Sensitivity and accuracy 2mV / DIV~5V / DIV
Vertical resolution 8 bit
Width of band (-3dB)  

DC(AC 10Hz) ~25MHz (DQ2025) ;DC(AC 10Hz) ~ 40MHz (DQ2040) 

DC(AC 10Hz) ~60MHz (DQ2060) ;DC(AC 10Hz) ~100MHz (DQ2100)
DC(AC 10Hz) ~150MHz (DQ2150) ;DC(AC 10Hz) ~200MHz (DQ2200)
Rise time ≤14ns (DQ2025)  ≤8.8ns(DQ2040)  ≤5.8ns(DQ2060)
≤3.5ns(DQ2100)  ≤2.3ns(DQ2150)  ≤1.8ns(DQ2200)
Sing-shot band width 25MHz
Input coupling DC , GND , AC
DC gain accuracy ±4% (2mV/DIV)   ±3% (5mV/DIV~5V/DIV)

Delta voltage Measurement accuracy

±(3%Rdg+0.05DIV)
HORIZONTAL SYSTEM
SEC/DIV range
5ns~5s/DIV
Sampling rate range N series: 500MSa/s  E series: 1GSa/s  DQ2025BN/CN:250MSa/s
Wave forn interplation (Sinx)/x
Record length 2 x 512k/channel
Sampling rate and delay Time accuracy ±100ppm over any ≥1mS time interval
Delta time Measurement accuracy ±(1 sampling interval time+ 100ppm x rdg +0.6nS)
TRIGGER SYSTEM

Acquisition Mode

AUTO, Normal, Single
Type Edge,TV, pulse, Width
Hold Off Range 100ns~1.5s
MATH +,-, ×, ÷
FFT
ACQUIRE INPUT
Input couping DC、AC or GND
Input impedance 1MΩ±2% 24pF±3pF
Probe attenuation 1x、10x、100x、1000x
Max.input voltage 400V (DC+AC peak) at 1KHz or less
Channel CMR Better than 40:1
Channel isolation Better than 40:1
DISPLAY
Persist time 1s, 2s, 5s
STORAGE Waveform, Setup. Bit
RECORDER Record, Replay
MEASUREMENT
Cursor Voltage difference△(V) between cursors
Time difference(△T) between cursors
Reciprocal of △T in Hz (1/△T)
AUTO-Mesure Vrms, Vavg,Vp-p,Vmax, Vmin, Vtop, Vhigh, Vlow, Vmid, Vamp;
period, Freq, Rise, Fall, +Width, +Duty, -Duty, Delay
I/O
Standard USB(D); USB(H); RS-232C (not for DQ2025BN)
Options LAN
CALIBRATOR SIGNAL
Output Voltage 3V (≥1MΩ load)
Output Frequency 1 kHz
POWER SOURCE 100/240VACrms, 45Hz~440Hz, 50VaMax; CAT II
ACCESSORIES One operation manual,Power cord, USB cable, probe2, Software CD-ROM
DIMENSIONS & WEIGHT 320(W) x 150(H) x 130(D)mm, Approx. 2.5kg
Copyright © Shanghai MCP Corp, 2011. All Rights Reserved
Add: Fl.3(East),Blk.4, Bai Da Industrial Park,No.1030 Tong Pu Rd., Shanghai, China
Tel: 86-21-52695961
Fax:86-21-52699261|Zip: 200333|E-mail: sales@mcpsh.com